<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-12 10-32-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 56 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 61 kHz 16940 3,8725
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,7 dBr 2,66 dBr 3,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 61 kHz MIN: 16 kHz % above 76 kHz: 3,8725 Acquired: 2024/08/12 10.31.24 Total samples: 16940 Equivalent time: 0:14:07 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400